Capacity Assessment Method of Air Compressor

Isolate the compressor along with its individual receiver that are to be taken for a test from the main compressed air system by tightly closing the isolation valve or blanking it, thus closing the receiver outlet.

Open the water drain valve and drain out water fully and empty the receiver and the pipeline. Make sure that the water trap line is tightly closed once again to start the test.

Start the compressor and activate the stopwatch.

Note the time taken to attain the normal operational pressure P2 (in the receiver) from initial pressure P1.

Free Air Delivery is to be corrected by a factor (273 + t1) / (273 + t2)

Calculate the capacity as per the below formula given.

Q = P2 - P1/P0 x V/T NM3/Minute

Where,
P2 = Final pressure after filling (kg/cm2a)
P1 = Initial pressure (kg/cm2a) after bleeding)
P0 = Atmospheric pressure (kg/cm2a)
V = Storage volume in m3 which includes receiver, after cooler and delivery piping
T = Time take to build up pressure to P2 in minutes

Popular posts from this blog

How to find out length of holding tube in pasteurizer?

Pasteurization requires that the milk is in custody for a specified time. The appropriate length for the holding tube can be calculated by the flow rate (Q) of milk and the diameter (D) of the holding tube using the formula: Length of holding tube, L = Q x holding time/A x Î· A = Area = pi/4 x sqr D Where an efficiency factor, η, of 0.85 is used in the model.

Specific power consumption of Air compressor

Specific Power Consumption   Specific power consumption is the ratio of the power consumed by an engine to a certain force such as the amount of output the engine (equipment) produces. It allows engines (equipments) of all different sizes to be compared to see which is the most power efficient. It allows manufacturers to see which engine (equipment) will use the least power while still producing a high amount of output. Specific power consumption of Air compressor The ratio of power consumption (in KW) to the volume delivered at ambient conditions. Specific power consumption= Actual power consumed by the compressor/Measured free air delivery If the measured flow is 250 m3/hr and actual power consumption is 30KW. Then Specific power requirement = 20 KW/250 m3/hr