How to measure clearance volume in reciprocating compressors?

Bumping clearance is checked by putting a lead ball or plastic gauges over the piston and then turning the compressor one revolution by hand.

By doing this the lead ball will compress and the thickness obtained is the clearance volume.

This thickness is measured with vernier caliper or micrometer and is then compared with the manufacturer’s value. Adjustments are made in case there is an offset in the value.

The clearance between piston and cylinder head while piston at TDC is called bumping clearance. This can be measured in different ways. One common method is, remove the valves from the top of the piston. Put a lead ball of sufficient diameter into the cylinder. Slowly turn the flywheel one revolution by hand. Take out the lead piece and measure its thickness, which gives the bumping clearance.
 

Popular posts from this blog

How to find out length of holding tube in pasteurizer?

Pasteurization requires that the milk is in custody for a specified time. The appropriate length for the holding tube can be calculated by the flow rate (Q) of milk and the diameter (D) of the holding tube using the formula: Length of holding tube, L = Q x holding time/A x Î· A = Area = pi/4 x sqr D Where an efficiency factor, η, of 0.85 is used in the model.

Specific power consumption of Air compressor

Specific Power Consumption   Specific power consumption is the ratio of the power consumed by an engine to a certain force such as the amount of output the engine (equipment) produces. It allows engines (equipments) of all different sizes to be compared to see which is the most power efficient. It allows manufacturers to see which engine (equipment) will use the least power while still producing a high amount of output. Specific power consumption of Air compressor The ratio of power consumption (in KW) to the volume delivered at ambient conditions. Specific power consumption= Actual power consumed by the compressor/Measured free air delivery If the measured flow is 250 m3/hr and actual power consumption is 30KW. Then Specific power requirement = 20 KW/250 m3/hr