Energy conservation opportunities in steam system

  • Use back pressure steam turbines to produce lower steam pressures.
  • Install PHE based hot water system in place of direct steam injection system
  • Ensure that piping, valves, fittings and vessels are well insulated.
  • Use more-efficient steam de-superheating methods.
  • Optimize the deaerator vent rate.
  • Ensure process temperatures are correctly controlled.
  • Maintain lowest acceptable process steam pressures.
  • Reduce hot water wastage to drain.
  • Clean boiler heat transfer surfaces on regular intervals.
  • Install pressure reducing station for low steam pressure.
  • Remove or blank off all redundant steam piping.
  • Replace non working line steam traps.
  • Improve water treatment to minimize boiler blow down.
  • Ensure condensate is returned or re-used in the process.
  • Preheat boiler feed-water.
  • Isolate steam from unused lines.
  • Recover energy from boiler blowdown.
  • Minimize excess combustion air.
  • Use high pressure condensate to make law pressure steam.
  • Check operation of steam traps.
  • Remove air from indirect steam using equipment.
  • Inspect steam traps regularly and repair malfunctioning traps promptly.

Popular posts from this blog

How to find out length of holding tube in pasteurizer?

Pasteurization requires that the milk is in custody for a specified time. The appropriate length for the holding tube can be calculated by the flow rate (Q) of milk and the diameter (D) of the holding tube using the formula: Length of holding tube, L = Q x holding time/A x Î· A = Area = pi/4 x sqr D Where an efficiency factor, η, of 0.85 is used in the model.

Specific power consumption of Air compressor

Specific Power Consumption   Specific power consumption is the ratio of the power consumed by an engine to a certain force such as the amount of output the engine (equipment) produces. It allows engines (equipments) of all different sizes to be compared to see which is the most power efficient. It allows manufacturers to see which engine (equipment) will use the least power while still producing a high amount of output. Specific power consumption of Air compressor The ratio of power consumption (in KW) to the volume delivered at ambient conditions. Specific power consumption= Actual power consumed by the compressor/Measured free air delivery If the measured flow is 250 m3/hr and actual power consumption is 30KW. Then Specific power requirement = 20 KW/250 m3/hr