Specific energy consumption of furnaces

Specific energy consumption of furnaces is very useful for comparing with design values or best practical norms.

There are many factors affecting furnace specific energy consumption such as capacity utilization of furnaces, final heating temperature, use of inefficient burner, excess air ratio, improper insulation/refractories, high stack loss etc... Specific energy consumption test is the key for assessing current performance of furnaces and finding the scope for improvements and productivity.

Specific Energy Consumption

 = Amount of Energy consumed in Kcal/hr / Quantity of material processed, Ton/Hr



If Amount of fuel consumed is 370 Kg/hr and amount of billet processed is 6 Ton/hr..

Then Specific fuel consumption of furnace 


= Amount of fuel consumed in Kg/hr / Amount of billet processed in Ton/Hr

= 380/6

Specific fuel consumption = 63.33 Kg of fuel/ tonne of billet

Popular posts from this blog

How to find out length of holding tube in pasteurizer?

Pasteurization requires that the milk is in custody for a specified time. The appropriate length for the holding tube can be calculated by the flow rate (Q) of milk and the diameter (D) of the holding tube using the formula: Length of holding tube, L = Q x holding time/A x Î· A = Area = pi/4 x sqr D Where an efficiency factor, η, of 0.85 is used in the model.

Specific power consumption of Air compressor

Specific Power Consumption   Specific power consumption is the ratio of the power consumed by an engine to a certain force such as the amount of output the engine (equipment) produces. It allows engines (equipments) of all different sizes to be compared to see which is the most power efficient. It allows manufacturers to see which engine (equipment) will use the least power while still producing a high amount of output. Specific power consumption of Air compressor The ratio of power consumption (in KW) to the volume delivered at ambient conditions. Specific power consumption= Actual power consumed by the compressor/Measured free air delivery If the measured flow is 250 m3/hr and actual power consumption is 30KW. Then Specific power requirement = 20 KW/250 m3/hr