What is bolt bound condition during shaft alignment?

Bolt-bound is when the movable machine is up against the hold down bolts preventing further adjustment in the direction needed to complete the horizontal alignment. It is used to describe a condition that occurs during the alignment process, where the driver or pump cannot be moved any further.

  • One is to re drill the base plate hole and or the foot hole to the require dimension to accommodate your calculated move.
  • Replace the existing bolts with smaller diameter bolts.
  • The best method to resolve this problem is to fill-weld the existing bolt hole, re-drill in the proper location, and re-tap. This problem can also be resolved by removing the problem equipment and increasing the diameter of the mounting holes in the feet.

Popular posts from this blog

How to find out length of holding tube in pasteurizer?

Pasteurization requires that the milk is in custody for a specified time. The appropriate length for the holding tube can be calculated by the flow rate (Q) of milk and the diameter (D) of the holding tube using the formula: Length of holding tube, L = Q x holding time/A x Î· A = Area = pi/4 x sqr D Where an efficiency factor, η, of 0.85 is used in the model.

Specific power consumption of Air compressor

Specific Power Consumption   Specific power consumption is the ratio of the power consumed by an engine to a certain force such as the amount of output the engine (equipment) produces. It allows engines (equipments) of all different sizes to be compared to see which is the most power efficient. It allows manufacturers to see which engine (equipment) will use the least power while still producing a high amount of output. Specific power consumption of Air compressor The ratio of power consumption (in KW) to the volume delivered at ambient conditions. Specific power consumption= Actual power consumed by the compressor/Measured free air delivery If the measured flow is 250 m3/hr and actual power consumption is 30KW. Then Specific power requirement = 20 KW/250 m3/hr